IGBTs are widely used in modern medium and high-power converters. Their switching characteristics determine the switching losses, power density, device stress, and electromagnetic compatibility of the equipment, directly affecting the performance of the converter. Therefore, accurately measuring the switching performance of power switching components is of great practical significance.
This system is a fully automated test system designed for the switching characteristics of IGBT devices and the reverse recovery characteristics of internal freewheeling diodes. It is suitable for testing the characteristic parameters of IGBT devices with a current less than 4500A, a collector voltage less than 6000V, and a freewheeling diode forward current less than 4500A.
System Units:
Turn-on Time Test Unit | The test units of this system generate current waveforms based on the principle of capacitor charging and discharging. During testing, the test voltage is set according to different test conditions, and the required current value is output by adjusting different inductance values or selecting different test pulse widths. The voltage and current waveforms are simultaneously captured by an oscilloscope, which communicates directly with the industrial computer to transmit the collected data to the computer. After processing, the test data is displayed in tabular form and can be edited and printed. |
Turn-off Time Test Unit | |
Gate Charge Test Unit | |
Computer Control Unit | |
PLC Control Unit | |
Pneumatic Pressure Fixture | |
Diode Reverse Recovery Test Unit |
Parameter Conditions
Turn-on Characteristics | Turn-off Characteristics | Pneumatic Fixture | |||
Test Parameters | Turn-on Delay | 10-1000ns±5%±10ns Tj=25ºC and 125 ºC | Turn-off Delay | 10-2000ns±5%±10nS Tj=25ºC and 125 ºC | Pressure: 5000Pa air compressor supply. Temperature Control Range: 25℃-200℃ Temperature Control Accuracy: ±1.0℃±1% Device Contact: 20 probe contact matrix |
Rise Time | 10-1000ns±5%±10ns Tj=25ºC and 125 ºC | Fall Time | 10-2000ns±5%±10nS Tj=25ºC and 125 ºC | ||
Turn-on Energy | 1-1000mJ±5%±0.1 mJ Tj=25ºC and 125 ºC | Turn-off Energy | 1-1000mJ±5%±0.1 mJ Tj=25ºC and 125 ºC | ||
Test Conditions | Collector Voltage | 50-3500V±5% Customized according to user requirements | Collector Voltage | 50-3500V±5% Customized according to user requirements | |
Collector Current | 50-1500A±5% Customized according to user requirements | Collector Current | 50-1500A±5% Customized according to user requirements | ||
Load | 20-1000uH | Load | 20-1000uH | ||
Gate Voltage | ±15V±3%±0.2V | ||||
Gate Charge | Single Short Circuit/ Pulse Width10uS / Short Circuit Current10KA | ||||
Short Circuit Test | Reverse Recovery Current/ Reverse Recovery Time / Reversedi / dt | ||||
Diode Reverse Parameters | 400-20000nC | ||||